Load-sensing central block for switching LS/constant current

Load-sensing central block for switching LS/constant current

Central blocks for switching between LS and constant current operation for closed-center blocks are offered here. Switching is done via the handwheel.

It also allows the generation of an LS signal via the seat valve. Damping and relief of the LS signal are already integrated. An adjustable pressure limit for the LS signal is also integrated.

Technical data:
- max. permissible pressure: 250 bar
- Adjustable max. LS pressure: 100-290 bar

- Max. flow rate in constant flow operation: 100 l/min
- Max. flow rate in LS operation: up to 250 l/min
- Switching voltage: 12 VDC
- P/T connections: 3/4" BSP and 1/2" BSP
- LS connection: 1/4" BSP